ISO 9001:2015 Certified | Cage Code: 7L0f6

TYPICAL PROPERTIES of NORYL® Modified PPO

ASTM or UL test Property Unfilled 30% Glass-filled
PHYSICAL
D792 Density (lb/in³)
(g/cm³)
0.039
1.08
0.049
1.36
D570 Water Absorption, 24 hrs (%) 0.07 0.06
MECHANICAL
D638 Tensile Strength (psi) 9,600 17,800
D638 Tensile Modulus (psi) 350,000
D638 Tensile Elongation at Break (%) 30
D790 Flexural Strength (psi) 13,500 20,000
D790 Flexural Modulus (psi) 360,000 1,100,000
D695 Compressive Strength (psi)
D695 Compressive Modulus (psi)
D785 Hardness, Rockwell R119 L108
D256 IZOD Notched Impact (ft-lb/in) 5.0 2.3
THERMAL
D696 Coefficient of Linear Thermal Expansion
(x 10-5 in./in./°F)
3.3 1.4
D648 Heat Deflection Temp (°F / °C)
at 264 psi
265 / 129 275 / 135
D3418 Vicat Softening Temp (°F / °C) 310 / 154 – / –
Max Operating Temp (°F / °C) 220 / 105 220 / 105
C177 Thermal Conductivity
(BTU-in/ft²-hr-°F)
(x 10-4 cal/cm-sec-°C)
1.32
4.55
1.94
6.68
UL94 Flammability Rating (1/4″ thick) V-0 V-0
ELECTRICAL
D149 Dielectric Strength (V/mil) short time, 1/8″ thick 500 530
D150 Dielectric Constant at 60 Hz 2.7 3.2
D150 Dissipation Factor at 60 Hz 0.001 0.002
D257 Volume Resistivity (ohm-cm)at 50% RH 1017 1017

NOTE: The information contained herein are typical values intended for reference and comparison purposes only. They should NOT be used as a basis for design specifications or quality control. Contact us for manufacturers’ complete material property datasheets.